Uygulama Prosedürü
GRAPHENE & GRAPHENE PRO
PROPERTIES
- 10H Hardness and N1 Silkiness
- Requires a single, thin coating
- Semi-permanent coating will not be affected by washing
- Fast & easy application
- Easy-to-clean
- High gloss finish
- Prevents color fading
- Protects painted bodywork, chrome, and exhaust
- Easily sheds dirt, rain, and snow
- Outstanding scratch resistance
- UV resistant
- Oxidation and corrosion resistant
- Advanced chemical and solvent resistance
- Cured coating may be re-coated, waxed or sealed over
- Withstands Extreme Temperatures
- Low VOC
- Low surface energy
PAINT PREPARATION
- Restore paint before application. Onyx Coating is not a paint restorer; any claying, polishing, and restoration work should be carried out before application.
- Best results are achieved with Body Shop Safe compounds containing no wax or fillers that will have to be removed before Onyx Coating application.
- Wash and dry paintwork.
- Remove wax and sealants from the paint surface. Use Onyx Coating Paint Prep using similar solvent-based paint prep product by applying enough to dampen a cloth and rub over the paintwork.
- Test an inconspicuous area to confirm compatibility, pay special attention to airbrushed or custom paintwork.
Depending on wax/sealant/tar deposits additional towel(s) may be needed. Do not leave Paint Prep dampened rags on paintwork.
APPLICATION
You may apply the product on a small section of a side window to gauge how quickly the product will dry at a given temperature. This way, you can apply the product to smaller sections to compensate for faster drying.
- Wipe on Onyx Surface Protection coating, covering an entire panel or panel section evenly with a thin coat. Any “touch-ups” of missed spots should be done after the initial product has been buffed (step 2). If additional coats are desired, wait until the initial coating is fully hardened (1-4 Hours).
- Approximately 1-5 minutes after application (depending on temperature and humidity) to the panel or section gently buff to a gloss with a dry microfiber towel. Do not allow the product to dry completely.
- In high (100° F +, 38° C +) temperatures drying time may need to be reduced to less than 1 minute ensure that coating not dried completely.
- If you notice any missed spots after buffing, you can re-treat the spot with Onyx Coating Resin and re-buff the area with a microfiber towel.
- Always test an inconspicuous area to confirm compatibility, pay special attention to airbrushed or custom paintwork.
- Be sure to check all areas after application to make sure no spots need re-buffing.
- Ready for light / dry driving after 8 hrs. Product cures within 4 hours. Coating will exhibit additional hardening over the next 7-14 days.
GRAPHENE AND GRAPHENE PRO NOTES AND PRE-CAUTIONS
DO NOT APPLY IN DIRECT SUNLIGHT – apply to a completely dry, cool surface.
- Misapplication can often be corrected by splitting the panel into smaller sections and reapplying the product as directed.
- For faster application, a microfiber sponge may be used as an applicator.
- Application is easiest when the product is applied at temperatures between 50-90°F (10-32°C).
- At higher temperatures, larger panels may be broken into two or more sections to compensate for faster evaporation of product.
- Overlapping application sections is OK when splitting a panel into sections.
- Use entire contents of bottle on one vehicle; the product should not be stored after opening.
- Pressure may build slowly in the container. Open the container
- Product is hydrolytically sensitive (reacts with moisture). Prevent the uncured product from coming into contact with water.
- Proper personal protective equipment should be used. A respirator is recommended for applications in closed and/or poorly ventilated areas. Solvent resistant gloves are recommended.
- Store product in a cool, dry place. Do not mix with other liquids.
PAINT PREP PRE-CLEAN NOTES
- Pressure may build slowly in the container. Open the container
- Proper personal protective equipment should be used. A respirator is recommended for applications in closed and poorly ventilated areas. Solvent resistant gloves are recommended.
- Do not leave soaked rags on painted surface. Do not leave on product on painted surface longer than 30 seconds.
- Do not allow Paint Prep to dry before wiping from the surface.
NOTES APPLICABLE TO ALL ONYX COATING PRODUCTS
IMPORTANT: KEEP AWAY FROM CHILDREN
- Do not ingest. If taken internally seek medical advice.
- Avoid contact with skin and eyes. May cause lung irritation.
- Keep the uncured product away from open flame and sources of ignition.
- Refer to MSDS for additional information.
- This application guide is not designed to serve as or be substituted for an MSDS on this product.
- When properly applied Onyx Coatings becomes permanently bonded and can only be removed by polishing (compounding) or wet sanding.
- Your use of Onyx Coating is an acknowledgement that you understand Onyx Coating Products forms a permanent bond with painted surfaces. User accepts full responsibility for any application issues.
- This product is intended for professional use. Application instructions need to be adhered to in order to achieve optimal results.
PRODUCTS APPLICATION VIDEO
Watch product application videos below: